FLIQUID_ConsistentPressure_UseDivV

(chamberwise) parameter to use numerical approximations of div(v) in direct computation of dynamic pressure (i.e. consistent pressure)

Default: FLIQUID_ConsistentPressure_UseDivV = 1 Use or DO NOT use the term containing the divergence of velocity in the Poisson equation for the dynamic pressure, see equations (3.43) and (3.44) in DOCUMATH_NumericalSchemeIncompressible.pdf. Note: This parameter can also be set chamberwise for multiphase simulations (see also KindOfProblem, CHAMBER). If it is not set for specific chambers, it is automatically set according to the non-chamberwise definition for all chambers.