BE_SmoothLength_RefreshAfterHowManyCycles
refresh the SMOOTH_LENGTH helper arrays after this many time cycles
Default: 10
Setting this parameter to 1 means, that the smoothing length definitions will be renewed as often as possible, irrespective of whether the internal criteria demands a renewal.
Setting a large value means, that the renewal of smoothing length definitions is mostly steered by the internal criteria.
The internal criteria include
-
- Has the activation status of a boundary element changed?
- Has the number of boundary elements changed?
- Is there a relevant change in the parameters of the SMOOTH_LENGTH specification?
- ...