%MOVE_MassChangeRate%

movement of free surface according to a given mass change rate

MOVE(0) = ( %MOVE_MassChangeRate%, MassChangeRate )
The VolumeChangeRate is mass/(area*time) = (density*volume)/(area*time). The normal velocity of the free surface is thus set to MassChangeRate/Y%ind_r%. Warning: This cannot be used together with VOLUME_correction_local yet.